picture |
Details
|
|
The IS25W- X is a fully regulated output voltage power supply. The output voltage is normally preset at the factory. Please consult Customer Services for your voltage requirements when ordering. | |
Note: | Universal AC input/ full range, Free air cooling convection |
Stock Code
|
Description
|
DC Output Voltage
|
Current
|
Efficiency
|
897.084.11
|
IS 25W-12
|
12V
|
2.1A
|
74% |
897.084.50 | IS 25W-24 | 24V | 1.1A | 80% |
Specifications | |
AC Input Voltage Range | 85-264VAC (120~370VDC) |
Inrush Current | Cold Start, 20A/115V, 40A/230V |
Load Regulation | <0.5% |
Line Regulation (220-240V) @ Full load | < ±0.5% |
Output Voltage Adjustable Range | ±10% |
Output Over Voltage Protection | 110~150% |
Output Over Load Protection | 110~150% |
Over Temperature Protection | IC, Tj:135ºC, Power Shutdown |
Withstand Voltage | I/P-O/P: 3.0KVAC/1min |
I/P-F/G: 1.5KVAC/1min | |
O/P-F/G: 0.5KVAC/1min | |
Rise, Hold Up Time | 50ms, 20ms @ Full Load (Tipical) |
Operating Temperature & Humidity | -10ºC~+50ºC, 20~93%RH (Non Condensing) |
Safety Standards | UL60950, EN60950 |
EMC Standards | Meet EN55022 Class B, EN61000 |
Connection | 2P, 4P/3.96mm Pitch |
Dimensions | 107x61x28(mm) |
Weight | 0.4kg |
The power supply is factory preset at the customer specified output voltage.
|
|
Installation
|
The power supply should be installed in a well ventilated area and not enclosed where excessive heat build up can occur. Do not install or mount above any hot air discharge/air-conditioner/radiator or similar equipment. Mounting outside or in a wet/damp environment is also not recommended. Keep fan intake/output vents well clear of any material likely to block them.
|
Batteries
|
The above power supplies are not suitable for charging the battery. |