picture |
Details
|
|
The IS 1000W-12 & IS 1000W-24 are fully regulated output voltage power supply. The output voltage is normally preset at the factory. Please consult Customer Services for your voltage requirements when ordering. | |
Note: | Compact size, Build in fan speed control, Over temperature & short circuit protection |
Stock Code
|
Description
|
DC Output Voltage
|
DC Output Current
|
Efficiency
|
897.084.91
|
IS 1000W-12
|
12V
|
84A
|
82%
|
897.084.92 | IS 1000W-24 | 24V | 42A | 84% |
Specifications | |
AC Input Voltage Range | 170-264VAC (210~370VDC) |
Input Frequency | 47~63Hz |
Inrush Current | 60A/230V |
Input Leakage Current | <0.7mA/230VAC |
Load Regulation | <1.0% |
Line Regulation (Full load) | < ±0.5% |
Output Voltage Adjustable Range | ±10% |
Output Over Current Protection | 110~130% |
Output Over Voltage Protection | 115~150% |
Withstand Voltage | I/P-O/P: 1.5KVAC/1min |
I/P-F/G: 1.5KVAC/1min | |
O/P-F/G: 0.5KVAC/1min | |
Rise, Hold Up Time | 50ms, 20ms @ Full Load (Tipical) |
Operating Temperature & Humidity | -10ºC~+50ºC, 20~90%RH (Non Condensing) |
Safety Standards | Design meet UL60950, EN60950 |
EMC Standards | Design meet EN55022 Class A |
Cooling Method | Fan |
Dimensions | 253x160x69(mm) |
Weight | 2.8kgs |
The power supply is factory preset at the customer specified output voltage.
|
|
Installation
|
The power supply should be installed in a well ventilated area and not enclosed where excessive heat build up can occur. Do not install or mount above any hot air discharge/air-conditioner/radiator or similar equipment. Mounting outside or in a wet/damp environment is also not recommended. Keep fan intake/output vents well clear of any material likely to block them.
|
Batteries
|
The above power supplies are not suitable for charging the battery |